Damper actuator for operating air control dampers in ventilation and air-conditioning systems for

building services installations

• For air control dampers up to approx. 4 m2

• Torque 20 Nm 

• Nominal voltage AC/DC 24 V

• Control: modulating DC 0 ... 10 V, position feedback DC 2 ... 10 V Technische Daten

Electrical data Nominal voltage AC 24 V, 50/60 Hz

DC 24 V

Nominal voltage range AC/DC 19.2 ... 28.8 V

Power consumption In operation

At rest

For wire sizing

2 W @ nominal torque

0.4 W

4 VA

Connection Cable 1 m, 4 x 0.75 mm2

Functional data Torque (nominal torque) Min. 20 Nm @ nominal voltage

Control Control signal Y

Working range

DC 0 ... 10 V, typical input impedance 100 kΩ

DC 2 ... 10 V

Position feedback (Measuring voltage) DC 2 ... 10 V, max. 1 mA

Position accuracy ±5%

Direction of rotation Reversible with switch 0 / 1

Direction of rotation at Y = 0 V at switch position 0 resp. 1

Manual override Gearing latch disengaged with pushbutton,

self-resetting

Angle of rotation Max. 95° , limited on both sides

by means of adjustable, mechanical end stops

Running time 150 s

Sound power level Max. 45 dB (A)

Position indication Mechanical, pluggable

Safety Protection class III Safety extra-low voltage

Degree of protection IP54 in any mounting position

EMC CE according to 89/336/EEC

Mode of operation Type 1 (to EN 60730-1)

Ambient temperature range –30 ... +50°C

Non-operating temperature –40 ... +80°C

Ambient humidity range 95% r.H., non-condensating (EN 60730-1)

Maintenance Maintenance-free

Dimensions / Weight Dimensions See «Dimensions» on page 2

Weight Approx. 1’050 g

Safety notes

The damper actuator is not allowed to be used outside the specified field of applica tion,

especially in aircraft or any other form of air transport.

• Assembly must be carried out by trained personnel. Any legal regulations or regulations

issued by authorities must be observed during assembly.

• The device may only be opened at the manufacturer‘s site. It does not contain any parts

that can be replaced or repaired by the user.

• The cable must not be removed from the device.

• When calculating the required torque, the specifications supplied by the damper

manufacturers (cross section, design, installation site), and the air flow conditions must

be observed.

• The device contains electrical and electronic components and is not allowed to be disposed

of as household refuse. All locally valid regulations and requirements must be observed.

Modulating damper actuator AC/DC 24 V, 20 Nm

Product features

Mode of operation The actuator is controlled by means of a standard control signal DC 0 ... 10 V. It opens to the

position dictated by this signal. The measuring voltage U allows the damper position (0 ... 100%)

to be electrically indicated and serves as a follow-up control signal for other actuators.

Simple direct mounting Simple direct mounting on the damper spindle with a universal spindle clamp, supplied with

an anti-rotation strap to prevent the actuator from rotating.

Manual override Manual operation is possible with the self-resetting pushbutton (the gearing latch remains

disengaged as long as the pushbutton is pressed).

Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops.

High functional reliability The actuator is overload-proof, requires no limit switches and automatically stops when the

end stop is reached.

Accessories

Description Data sheet

Electrical accessories Auxiliary switch S..A.. T2 - S..A..

Feedback potentiometer P..A.. T2 - P..A..

Range controller SBG24 T2 - SBG24

Positioner SG..24 T2 - SG..24

Digital position indication ZAD24 T2 - ZAD24

Mechanical accessories Various accessories (clamps, shaft extensions etc.) T2 - Z-SM..A..

Electrical installation

Wiring diagrams

Y

U

1 2 3 5

DC 0…10 V

DC 2…10 V

– +

~ T

Dimensions [mm]

Dimensional drawings

139

56

64

30 109 41

88

Damper spindle Length

Clamp on top min. 42 10 ... 20 (26.7)

Clamp on bottom min. 20 10 ... 20

Notes

• Connection via safety isolating transformer.

• Other actuators can be connected in parallel.

Please note the performance data.

Technical data sheet Damper actuator motorized damper install Duct sensor for relative humidity and temperature

Technical data sheet Damper actuator motorized damper install Duct sensor for relative humidity and temperature


Technical data sheet Damper actuator motorized damper install Duct sensor for relative humidity and temperature

Technical data sheet Damper actuator motorized damper install


Technical data sheet Damper actuator motorized damper install Duct sensor for relative humidity and temperature

Technical data sheet Damper actuator motorized damper install Duct sensor for relative humidity and temperature

Technical data sheet Damper actuator motorized damper install Duct sensor for relative humidity and temperature
Technical data sheet Damper actuator motorized damper install Duct sensor for relative humidity and temperature


Duct sensor for relative humidity and temperature

EN Datasheet


Subject to technical alteration

Issue date 2007/01/27


Duct sensor for relative humidity and temperature

Application
Duct sensor for measuring relative humidity and temperature in gaseous
media of heating, cooling and airconditioning
systems (e.g. in fresh air/
exhaust air ducts). Designed for locking on control and display systems.
Additionally, the device can be supplied with a passive temperature sensor
e.g. PT100, PT1000, NTC10k etc.
Types Available
LCNFTK140VV
Duct sensor 140mm, output 0...10V,
with transducer for temperature, output 0...10V
LCNFTK270VV
Duct sensor 270mm, output 0...10V,
with transducer for temperature, output 0...10V
LCNFTK400VV
Duct sensor 400mm, output 0...10V,
with transducer for temperature, output 0...10V
Norms and Standards
CEConformity:
89/336/EWG Electromagnetic compatibility
Standards: EN 607301:
2000
EN 6100042
EN 6100043
EN 6100044
EN 6100045
EN 6100046
EN 55022B
Technical Data Hardware
Power supply: 1524VDC/
24AC +/10%
Power consumption: typ. 0,5W / 1,7VA
Measuring range: Humidity: 0...100%rH
Temp. 20...+
80°C
Output: Humidity: 0...10VDC, load: min. 5kOhm
Temp.: 0...10VDC, load: min. 5kOhm
(Optional Type VS: Resistance NTC/PTC)
Clamps: Terminal screw max. 1,5mm²
Mounting length L: 140mm/270mm/400mm
Sensor pipe: Material PA6, colour black
Filter element: Material stainlesssteel,
mesh size 80μm
Connection head: Material PA6, colour white
Protection: Connection head IP65
Cable entry: Single entry M16 for cable max. D=8mm
Ambient temperature: 20...+
70°C
Accuracy
Temperatur, absolute Genauigkeit
Temperature, absolute accuracy
±0°C
±1°C
±2°C
±3°C
20°
C 10°
C 0°C 10°C 20°C 25°C 30°C 40°C 50°C 60°C 70°C 80°C
Mounting Advice
The sensor is directly mounted to the ventilation duct by means of a
mounting flange or by screws.
Please also note our general remarks in our INFOBLATT THK.
Duct sensor for relative humidity and temperature

Electrical connection
The devices are constructed for the operation of protective low voltage
(SELV). For the electrical connection, the technical data of the
corresponding device are valid. Specially with regard to passive sensors
(e.g. PT100 etc.) in 2wire
conductor versions, the wire resistance of the
supply wire has to be considered. Probably, the same has to be
compensated by the following electronics. Due to the selfheating,
the wire
current affects the accuracy of the measurement. Thus, the same should
not exceed 1mA.
Application Notice
Due to air circulations dirt and dust particles can be piled up in the
course of time on the sintered filter which is protecting the sensor.
Thus, the function of the sensor can be affected. After having
dismantled the filter, the same can be cleaned by blowing it out with oilfree
and filtered compressed air, superclean
air or nitrogen or by
washing it out with distilled water. If the filter is too dirty, the same
should be replaced.
Refrain from touching the sensitive humidity sensor. Any touch of the
same will result in an expiration of the warranty.
When using the sensor in aggressive gases, an early recalibration or a
change of the humidity sensor can become necessarily. Such a
recalibration or a probable sensor change do not come under the
general warranty.
Optional Accessories
(MF19PA)
Mounting flange for installation on ventilation duct
Mounting flange for installation on ventilation duct